Basic introduction
ITE Information Technology Equipment Its main function is to be able to enter, store, display, retrieve, transfer, process, exchange or control (or a combination of several functions) data and telecommunication messages. The device can be configured with one or more commonly used The terminal port for information transmission; its rated voltage does not exceed 600V.
Common ITE products
ITE includes data processing equipment, office equipment, electronic business equipment, and telecommunications equipment.
Such as: personal computers, laptops, tablets, mice, keyboards, monitors, all-in-ones, printers, projectors, routers, scanners, U disks, mobile hard drives, various computer peripherals and accessories.
EU CE certification
Test standards: E55022, EN55024, EN61000-3-2, EN61000-3-3
Electromagnetic compatibility directive: 2004/108 / EC
Test item EMI part:
project
|
Frequency range
|
standard
|
Power side conduction (CE)
|
0.15 ~ 300MHz
|
EN55022
|
Telecommunication end conduction (ISN)
|
0.15 ~ 300MHz
|
EN55022
|
Space Fu shoot (RE)
|
300Hz ~ 66GHz
|
EN55022
|
If the maximum frequency of the internal source of the product is lower than 106 / 0Hz, the measurement is performed to 1GHz
If the maximum frequency of the internal source of the product is between 1080 / 0Hz50000tz, the amount is up to 2GHz
If the maximum frequency of the internal source of the product is between 5000Hz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 16Hz, the measurement is performed to 5 times the maximum frequency or 66Hz, whichever is the less
Harmonic
standard
|
EN61000-3-2
|
Rated voltage range is AC220 ~ 240V
|
Products need to be tested for this project
|
Rated power 75W and below
|
Unlimited product regulations, no testing required
|
Voltage fluctuation, flicker (Plicker)
standard
|
EN61000-3-3
|
Rated voltage range is AC220 ~ 240V
|
Products need to be tested for this project
|
Limit requirements:
|
Short-term flash value Pst≤1.0
Long-term flash value P1t≤0.65
Relative steady state voltage change dc≤3.3%
Maximum corresponding voltage change nax≤4%
|
Testing project EMS part:
Electrostatic Immunity (ESD)
Standard: EN55024 (refer to IEC61000-4-2); performance criterion: A
Contact discharge: ± 4kV: 25 times of polarity at each discharge point
Air discharge: ± 8kV; each discharge point has 10 times polarity
Radiation immunity (RS)
Standard: EN55024 (refer to IEC61000-4-3); performance criterion: A
Frequency range: 80 ~ 100000Hz
Frequency range: 80 ~ 100000Hz
Electrical Fast Transient Burst (EFT)
Standard: EN55024 (refer to IEC61000-4-4) Performance criterion: B
Test specifications:
AC power input: 1kV; repetition frequency 5kHz
DC power input: 0.5kV; repetition frequency: 5kHz
Signal port and telecommunication port: 0.5kV; repetition frequency 5kHz
This test is not required for interface ports connected to data cables specified by the manufacturer with an expected length of 3 m or less
Lightning Immunity (Surge)
Standard EN55024 (refer to IEC61000-4-5 ITU-T K20, K21, K22)
Performance criterion B
Test specifications:
AC input: 1.2 / 50 (8/20) combined wave; line-line: 1kV; line-ground: 2kV
DC input: 1.2 / 50 (8/20) combined wave; 0.5kV
Only applicable to ports that may be directly connected to outdoor cables according to the manufacturer's specifications
Signal and telecommunication ports: 10/700 waveform; 1kV or 4kV
Only applicable to ports that may be directly connected to outdoor cables according to the manufacturer's specifications; if the port is provided with the first level of protection as required, the test shall be applied
4kV voltage to the set protector; otherwise, apply 1kV test voltage to the port without protector.
Conducted immunity (CS)
Power frequency magnetic field immunity (MS)
Voltage drop, short-term interruption immunity (Dips)
EMS performance criteria
Performance criterion A:
No operator intervention is required and the equipment should continue to work as expected. When the equipment is used as intended, no degradation or loss of function below the performance level specified by the manufacturer is allowed. Performance levels can be replaced with allowable performance degradation. If the manufacturer does not specify a minimum performance level and allowable performance degradation, it can be known from the product description or technical file, and the user has reason to require the equipment used to meet this requirement.
Performance criterion B:
After the test has started, no operator intervention is required and the equipment should continue to function as intended. When the equipment is used as intended, no performance degradation or loss of function below the manufacturer's specifications after the disturbance is imposed. The performance level can be replaced with an allowable performance reduction. During the test, performance degradation is allowed. However, after the test, the working status should not change and the stored data should not be lost. If the manufacturer does not specify a minimum performance level and allowable performance degradation, it can be known from the product description or technical file, and the user has reason to require the equipment used to meet this requirement.
Performance criterion C:
A loss of functionality is allowed that can be restored by itself or can be restored by the user following the manufacturer's instructions.
Features and / or information stored in non-volatile memory or protected by a backup battery should not be lost.
US FCC certification & Canadian IC certification
Certification form: FCC DOC
Detection standard: FCC 47CFR Part 15B
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 40GHz
If the maximum frequency of the internal source of the product is between 1.705 ~ 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the highest frequency of the internal source of the product is higher than 1GHz, the measurement is performed to the fifth harmonic of the highest frequency 5 times or 40GHz, whichever is the smaller
Canadian IC certification
Detection Standard: ICES-003
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 40GHz
If the maximum frequency of the internal source of the product is between 1.705 ~ 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the highest frequency of the internal source of the product is higher than 1GHz, the measurement is performed to the fifth harmonic of the highest frequency 5 times or 40GHz, whichever is the lesser.
China CCC certification
Testing standards: GB9524, GB17625.1
Test items:
Item Frequency range Standard
Power side conduction (CE) 0.15 ~ 30MHz GB9524
Telecommunication end conduction (ISN) 0.15 ~ 30MHz Gb9524 GB9524
Space radiation (RE) 30MHz ~ 6GHz GB9524
If the maximum frequency of the internal source of the product is lower than 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement is performed to 5 times or 6GHz of the highest frequency, whichever is the lesser.
Harmonic
Standard: GB17625.1
Products with a rated voltage range of AC220 ~ 240V need to be tested for this project
Unlimited value for products with rated power 75W and below, no test required
Australian RCM certification
Detection standard: AS / NZSCISPR22
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Telecom end conduction (ISN) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 6GHz
If the maximum frequency of the internal source of the product is lower than 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement is performed to 5 times or 6GHz of the highest frequency, whichever is the lesser.
Japan VCCI certification
Detection standard: VCCI-V3
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Telecom end conduction (ISN) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 6GHz
If the maximum frequency of the internal source of the product is lower than 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement is performed to 5 times or 6GHz of the highest frequency, whichever is the lesser.
KC certification
Detection standard: KN22, KN24
Test items (EMI part):
Item Frequency range Standard
Power side conduction (CE) 0.15 ~ 30MHz KN22
Telecom end conduction (ISN) 0.15 ~ 30MHz KN22
Space radiation (RE) 30MHz ~ 6GHz KN22
If the maximum frequency of the internal source of the product is lower than 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement is performed to 5 times or 6GHz of the highest frequency, whichever is the lesser.
Taiwan BSMI certification
Detection standard: CNS13438
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Telecom end conduction (ISN) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 6GHz
If the maximum frequency of the internal source of the product is lower than 108MHz, the measurement is performed to 1GHz
If the highest frequency of the internal source of the product is between 108MHz ~ 500MHz, the measurement is performed to 2GHz
If the maximum frequency of the internal source of the product is between 500MHz ~ 1GHz, the measurement is performed to 5GHz
If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement is performed to 5 times or 6GHz of the highest frequency, whichever is the lesser.